Skip to Main Content
Cognex 支持中心
LogoLogo

The Focus is Not Adjusted on the Left and Right Sides of the Field of View

Explanation for visual distortion in Wafer ID acquisition

2024/09/15

Details

Issue:

The focus is slightly out of focus on the left and right sides of the visual field, and the focus is near the center. Is this a malfunction?

Probable Causes:

  • Although there are some differences, this is an expected situation, as due to the lensing present the images tends not to be focused at the extreme left and right of the visual field.  However in rare cases there are certain lenses whose extremity blur is greater than expected.

Solution:

  • First, make sure that the Wafer ID and the wafers are placed in parallel.
  • In most cases, the lowered focus does not affect the reading ability. However, for lenses with particularly bad distortion, the unit may require replacement.

相关资源