Issue:
ReadIDMax function fails to decode interleaved 2 of 5 code containing fewer than 6 characters, both on the In-Sight Explorer and In-Sight Vision Suite platforms.

Cause:
The interleaved 2 of 5 code have a default of minimum 6 characters per the barcode spec recommendation and it can go up to 80 characters.
Resolution:
Use SetSymbolMinStringLength(ReadIDCellRef,73,1) to expand the accepted character length for I2of5.