VisionPro pUnk Issues

Explanation and troubleshooting steps for receiving pUnk errors in VisionPro

2024. 09. 15.

Details

Issue:
QuickBuild, CogTool and/or VisionPro applications report an error similar to below:

Unexpected error from CogAcqFifoCtlV2: Value cannot be null.

Parameter name: pUnk

placeholder

Cause:
Most frequently, this error is due to one or more acquisition modules not initializing properly. Unfortunately, the acquisition modules have many dependencies, so the cause varies.

Resolution:
The following steps have had some success with users:

  • Uninstalling the 3rd party software such as Basler's Pylon SDK or Allied Vision's Vimba SDK when it is not needed.
  • Alternately, disable Cognex GenTL acquisition module, so that VisionPro will not attempt to load or use the 3rd party producer.

Additionally:

GenTL producers may be failing to load. Check that third party camera software is functional without Cognex (e.g. pylon Viewer, Allied Vision SmartView, etc.).

The GENICAM_CACHE_V2_4, GENICAM_ROOT_V2_4, GENICAM_ROOT, GENICAM_GENTL32_PATH and/or GENICAM_GENTL64_PATH environment variables may be incorrect (note that older versions of Cognex software use older versions of GenICam). The environment variables should be set as follows:

  • GENICAM_CACHE_V*: <Installation directory>\Cognex\Common\genicam\cache
  • GENICAM_ROOT_V*: <Installation directory>\Cognex\Common\genicam
  • GENICAM_ROOT: <Installation directory>\Cognex\Common\genicam
  • GENICAM_GENTL32_PATH: A semicolon separated list of directories containing the *.cti files and possibly other supporting files. This value is not used for 64-bit installations.
  • GENICAM_GENTL64_PATH: A semicolon separated list of directories containing the *.cti files and possibly other supporting files. This value is not used for 32-bit installations.

GenICam DLL’s, Pleora drivers may be missing, or other installation problems might be present. Consider reinstalling.