output.content vs output.telnet

Summary of the difference between output.content and output.telnet in DataMan scripting with relation to Edge Intelligence

2024. 09. 18.

Question

What is the difference between output.content and output.telnet in DataMan scripting in my Edge Intelligence setup?

 

Answer

  • DataMan - Edge Intelligence (Standard Results)
  • Edge Intelligence Essentials gets the DataMan results from output.telnet.
  • output.telnet will get the value of output.content if it’s not set.
  • If output.telnet and output.content both are set, Edge Intelligence will get whatever is set on output.telnet.

 

DataMan - Edge Intelligence (Tunnel Trigger Results)

  • Tunnel Manager systems doesn't use output.telnet for the "Tunnel Trigger Result".
  • Tunnel Manager gets its data through port 47777.

 

Dataman - PLC

  • DataMan also interacts with PLC using a variety of factory floor protocols, That communication goes through output.IndustrialProtocol.
  • If PLC communication is configured to be sent via output.telnet, then that will also be fed to Edge Intelligence's "Standard" Trigger results.
     

Types of protocol use for PLCs

  • If you're using a Mitsubishi PLC, then you'd probably use SLMP.
  • If you're using a Siemens PLC, then Profinet.
  • If you're using Rockwell/Allen-Bradley, then EtherNet/IP

 

More detailed information around DataMan to Edge Intelligence interaction can be found here: https://cogfluence.pc.cognex.com/x/dJj3E