In-Sight 3800 - ENET0 and ENET1  

For the In-Sight 3800, ENET0 can be used for connections to ISVS, Web HMI, TCP/IP, OPC/UA, FTP, and FFP (Ethernet/IP, Profinet, SLMP, etc.)  ENET1 can be used for connection to ISVS, Web HMI, TCP/IP, OPC/UA, FTP

17/12/2024

Question

What is supported on ENET 0 and ENET 1?

Answer

ENET0: Connection to ISVS, Web HMI, TCP/IP, OPC/UA, FTP, and FFP (Ethernet/IP, Profinet, SLMP, etc.)

ENET1: Connection to ISVS, Web HMI, TCP/IP, OPC/UA, FTP

Only one connection to ISVS at a time is supported. You cannot connect to ISVS on both ethernet ports simultaneously.

Only one FFP (Factory Floor Protocol) can be used at once across both ethernet connections. FFPs include Profinet, EtherNet/IP, and SLMP.

Recommended to use ENET0 for FFP as it is required for both Profinet, Ethernet/IP, and SLMP

For high-speed applications with FFP, it is recommended to connect to ISVS with ENET1

The Web HMI CAN be connected to both ethernet ports simultaneously.

Example Valid Configurations:

  • ENET0 = Profinet; ENET1 = ISVS, FTP;
  • ENET0 = ISVS; ENET1 = TCP/IP, FTP;
  • ENET0 = Profinet, FTP; ENET1 = OPC/UA, ISVS; 

 