ReadIDMax cannot read interleaved 2 of 5 code but ReadIDCode can.

21.10.2025

Issue:

ReadIDMax function fails to decode interleaved 2 of 5 code containing fewer than 6 characters, both on the In-Sight Explorer and In-Sight Vision Suite platforms.

ReadIDMax Cannot Decode Interleaved 2 Of 5 Code_Image-1

Cause:

The interleaved 2 of 5 code have a default of minimum 6 characters per the barcode spec recommendation and it can go up to 80 characters.

Resolution:  

            Use SetSymbolMinStringLength(ReadIDCellRef,73,1) to expand the accepted character length for I2of5.