In-Sight Firmware Version Displays as 10.0.1.xx

Fix for issue with In-Sight showing an invalid Firmware version

15.09.2024

Details

Issue:

In-Sight Firmware version displays as 10.0.1.xx.

Causes:

This can occurs after an unexpected interruption during upgrade/downgrade FW.

Resolution:

Check to see if the following indicator lights are lit:

ENET LED is green, LED1 or LED2 is red.

Placeholder

If this is the case, In-Sight Explorer can detect the system. Set a proper IP address and double click to connect. You should see a connection error in red pop up.

Placeholder

Check the Firmware version display to see if it lists 10.0.1.xx.

Placeholder

If these symptoms are found, then the system can be recovered by re-upgrading to an available Firmware version. It is possible the update may fail again, in which case please power it off and try again.

Note: In-Sight 8505 cannot be downgraded to 6.2.1 or lower. 